Matt Barney started the topic Curious sensor failures and cyclical measurements in the forum Mayfly Data Logger 1 years, 5 months ago
Curious sensor failures and cyclical measurements
We have a station with HYDROS-21 and Turner Turbidity+ sensors. Beginning on 12/30/22 the HYDROS appears to have quit communicating, reporting only values of -9999 for all its variables. Near the same time, the Turner began reporting values with a daily cyclical pattern: higher in midday, and…[Read more]
neilh20 replied to the topic Systems not recognized from 12th( v0.15.0?) in the forum Monitor My Watershed 1 years, 5 months ago
Well, I’m back at my desk, with a Mayfly and powered it up, and I’m posting to
Host: monitormywatershed.org
and getting
— Response Code — 301 waited 326 mS Timeout 8000
If I change it to
Host: data.envirodiy.org
— Response Code — 201 waited 577 mS Timeout 8000
From https://github.com/ODM2/ODM2DataSharingPortal/issues/542
[Read more]
Jim Moore replied to the topic Erratic EC response of Hydros 21 sensors in the forum Monitor My Watershed 1 years, 5 months ago
Thanks for the input, Dan@wachusett. I think I figured out my problem – it was the bubbles in the stream as you can see in the attached photo when I was co-locating two sensors! I moved the sensor probe about a foot to calmer waters and now the results look normal.
dan@wachusett replied to the topic Erratic EC response of Hydros 21 sensors in the forum Monitor My Watershed 1 years, 5 months ago
Jim,
I have seen similar fluctuations in some of the streams where I have Hydros21 sensors. Typically, step changes > 100 µS in 5 or 15 minutes only occur during runoff/snowmelt events. In the winter, after a snow event with road salt application and subsequent melt I have seen > 2,000 µS fluctuations in 15 minutes as the salt pulses work their w…[Read more]
dan@wachusett started the topic Modbus communications on Keller CTD Sensor in the forum Environmental Sensors 1 years, 5 months ago
Hello,
I am looking for some help troubleshooting modbus communications on a Keller CTD sensor. I am running the very basic KellerTest sketch on a Mayfly 0.5b board with a RS-485 half shield adapter board. I turned on debugging to get some extra information.
[Read more]
Jim Moore replied to the topic Erratic EC response of Hydros 21 sensors in the forum Monitor My Watershed 1 years, 5 months ago
smaller file sent
Jim Moore started the topic Erratic EC response of Hydros 21 sensors in the forum Monitor My Watershed 1 years, 5 months ago
I have a Mayfly sensor station on a small perennial trib to Marsh Creek. I was noticing step changes in the EC of over 100µS in the 5 minute sampling interval. Suspecting that this was a defective sensor so I co-located another sensor and got a similar result and the two EC readings were uncorrelated. Therefor I put both sensors in a filled bu…[Read more]
Sara Damiano replied to the topic Data download not working in the forum Monitor My Watershed 1 years, 5 months ago
I don’t know whether the data is lost or not. I’ll look into it.
Jim Moore replied to the topic Data download not working in the forum Monitor My Watershed 1 years, 5 months ago
The MMW server is working now but there is a data gap between 5/12 @15:00 and 5/13 @ 07:15. Will that data be restored or will we need to rely on the station SD card?
Jim Moore replied to the topic Data download not working in the forum Monitor My Watershed 1 years, 5 months ago
I have been getting “server error(500)” for the last two days on all stations I attempt to load.