Matt Barney replied to the topic Modem Alternatives (Verizon certified) in the forum Mayfly Data Logger 1 years, 6 months ago
We purchased NimbeLink’s Verizon SIMs, and we activate them and purchase service directly from NimbeLink, so never had to deal with Verizon itself.
I did contact SIMCom (maker of the modem chip on the LTEBee modems) about Verizon certification, and they said they were still awaiting it. Then they notified me once they received Verizon…[Read more]
Jake Lemon started the topic Monitor My Watershed Sites in the forum Monitor My Watershed 1 years, 6 months ago
Hi All. I updated my MMW password after the V0.15 release. Now I am not seeing most of my sites under “My Sites”. Perhaps I have multiple profiles somehow and I’ve connected to an old one in the process of updating my password? The only sites are see are two from PA that were deployed in 2017 I think. Can someone please look into that for me? Thanks!
Shannon Hicks replied to the topic SDI-12 sensor power supply – is 12 V needed? in the forum Environmental Sensors 1 years, 6 months ago
SDI-12 sensors usually use 12 volts for sensor excitation because that’s what the specification for the protocol dictates. Fun fact: the “12” part of “SDI-12” does not refer to the voltage, but rather the baud rate, so the name actually means “serial-digital interface at 1200 baud”). Back in the days when the protocol was first being used, mo…[Read more]
dan@wachusett replied to the topic Modem Alternatives (Verizon certified) in the forum Mayfly Data Logger 1 years, 6 months ago
Matt, I did see that thread about the SIM and APN details, and have no doubt that the modems will work. The trouble is that our Verizon rep (as of January 2023) does not see the EnviroDIY modem IMEI numbers in their device database, therefore they will not “activate” them on our plan. We have SIM cards operating on the Verizon network now using…[Read more]
Pavel started the topic SDI-12 sensor power supply – is 12 V needed? in the forum Environmental Sensors 1 years, 6 months ago
Usually SDI-12 sensors use 12 V power supply. In SDI-12 specification there is stated that logger should provide voltage in range 9.6 V to 16 V. I have checked sensors I commonly use (mostly Meter) and they all work with power supply 5 V or even lower. I would say using lower power supply volatage for sensors should also lead to more efficiency…[Read more]
neilh20 replied to the topic Systems not recognized from 12th( v0.15.0?) in the forum Monitor My Watershed 1 years, 6 months ago
Thanks for looking into it.
I’m in the UK for my Uncle who had a stroke, and I took off very quickly from California, and not likely to get back before the end of May after his funeral. I haven’t brought any tools to see what the response are from the server.
It seems very unlikely that 5 systems would all stop transmitting by themselves. My…[Read more]
Anthony Aufdenkampe replied to the topic Systems not recognized from 12th( v0.15.0?) in the forum Monitor My Watershed 1 years, 6 months ago
@neilh20, We just looked at the database and the server logs and found the following.
<p style=”font-weight: 400;”>Only 5 sampling features stopped reporting new data on April 12.</p>
<ul style=”font-weight: 400;”>
<p style=”font-weight: 400;”>These stations have not attempted to post…[Read more]
Heather Brooks replied to the topic Systems not recognized from 12th( v0.15.0?) in the forum Monitor My Watershed 1 years, 6 months ago
Thanks for reporting, @neilh2O. I’ve verified that your sites are still not updating and notified the Monitor My Watershed development team. I’ll let you know when I hear back.
James_NZ replied to the topic Hydros 21 Gen 2 -9992 values in the forum Environmental Sensors 1 years, 6 months ago
METER replied:
I am so sorry. That error means that there is some kind of error with the calibration of the sensor. I will have one of my colleagues reach out to you with a return material authorization (RMA) to have that instrument brought in to have the issue fixed.
James
neilh20 started the topic Systems not recognized from 12th( v0.15.0?) in the forum Monitor My Watershed 1 years, 6 months ago
Just wondering if anybody seeing MMW not showing systems
There is one station working fine, over cellnet https://monitormywatershed.org/sites/TUCA-Na13/
And three systems not reporting
https://monitormywatershed.org/sites/TUCA_Sa01/ last update <span class=”last-observation”>April 12, 2023, 5 a.m.…[Read more]