Shannon Hicks replied to the topic Clarivue10 data logging problems in the forum Mayfly Data Logger 1 months, 2 weeks ago
I assume you are using a Mayfly v1.1 board and not an older v1.0, because it had a hard time providing a stable 12v for that particular type of sensor. But are you using the onboard 12v source by selecting 12v on the Grove voltage selector jumper, or are you using one of the new screw terminal boards that has its own 12v boost circuit on it?
-
Dave Bressler replied to the topic Monitor My Watershed Classes in the forum Monitor My Watershed 1 months, 2 weeks ago
There are no workshops scheduled yet for 2025, but you can review past events and check in from time to time for new events under the Participate tab, https://www.envirodiy.org/envirodiy-events/.
-
Shannon Hicks replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 1 months, 2 weeks ago
That all looks correct. I usually put the Mayfly’s analog Grove jack voltage selector jumper to the 5v position because the old sensors required 5v for excitation, but supposedly these newer ones are happy with 3v to 15v, but we still use them at 5v and calibrate them with that excitation voltage. If you connect the 6-pin screw terminal board s…[Read more]
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 1 months, 2 weeks ago
Shannon,
I attached a picture of how I am connecting the C-FLOUR to the multipurpose screw terminal board. Can you let me know if this is the correct wiring and resistor amount, type, and location?
Thank you.
-
Elliot Ma started the topic Clarivue10 data logging problems in the forum Mayfly Data Logger 1 months, 2 weeks ago
We installed a ClariVUE10 turbidity sensor with a data logger in a creek a couple of months ago. It was working well and uploading data to MonitorMyWatershed.org without issues until 10/17, when it started reporting -9999 values for turbidity. We’ve verified that the sensor wiring is intact, and the internals of the logger appear to be f…[Read more]
-
Jonesy replied to the topic Can't add EnviroDIY ATmega Boards in the forum Mayfly Data Logger 1 months, 2 weeks ago
Hi,
Was a firewall at my school…got it fixed now. Thanks a lot!
-
Paulins Kill Watershed Community started the topic Monitor My Watershed Classes in the forum Monitor My Watershed 1 months, 2 weeks ago
Hi there and I am happy to become a part of this project. I would like to speak with a person regarding equipment and setting up a monitoring system. Friends at other watersheds have indicated that stream equipment/ system trainings are available. How do I locate these classes?
-
Paulins Kill Watershed Community became a registered member 1 months, 2 weeks ago
-
Shannon Hicks replied to the topic Can't add EnviroDIY ATmega Boards in the forum Mayfly Data Logger 1 months, 3 weeks ago
The file is there. Is your computer behind a firewall that is blocking github? What happens if you click on the link for the EnviroDIY json file? You should see a simple text webpage with some code talking about packages and platforms.
-
Jonesy started the topic Can't add EnviroDIY ATmega Boards in the forum Mayfly Data Logger 1 months, 3 weeks ago
Hello,
I keep getting an error message when trying to download the EnviroDIY ATmega Board via this link on the software page:
https://raw.githubusercontent.com/EnviroDIY/Arduino_boards/master/package_EnviroDIY_index.json
Error message received:
Error downloading…[Read more]
-
Shannon Hicks replied to the topic Inconsistent and erroneous analog differential measurements in the forum Mayfly Data Logger 1 months, 3 weeks ago
Can you email me your code at mayfly@envirodiy.org so I can take a look at it? How many other adafruit ADC boards do you have attached to the Mayfly in question and are they the 12-bit or 16-bit versions? The Mayfly’s ADC is permanently set to 0x48. What is the typical and maximum voltages you should see on the sensor?
-
Shannon Hicks replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 1 months, 3 weeks ago
The two sensor models perform exactly the same. We’ve used a couple in the field with existing loggers when replacing some old broken Cyclops 7f sensors. All we did was swap the sensors and redo the calibration and edit the appropriate 2 lines in the code for the voltage measured in the standard and the blank (nanopure water). The C-FLUOR se…[Read more]
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 1 months, 3 weeks ago
<div>Hi Shannon,</div>
<div></div>
<div>I ordered a C-FLOUR not realizing that the modular sensor library only has compatibility with the Cyclops-7F, even though you mentioned the Cyclops in your earlier post.</div>
<div></div>
<div>Based on what a rep has told me, Turner is starting to phase out their Cyclops-7F sensors and replacing them with…[Read more] -
Jonesy became a registered member 1 months, 3 weeks ago
-
Braedon started the topic Inconsistent and erroneous analog differential measurements in the forum Mayfly Data Logger 1 months, 3 weeks ago
I am having some difficulty getting consistent results using the Mayfly’s auxiliary 16-bit ADC. I have multiple stations set up that use the same code and wiring, but for some reason the measurements being recorded are not behaving as I would expect. For context, I am using Apogee’s shortwave pyranometers (both upward and downward looking) on the…[Read more]
-
Douglas Wood started the topic Seametrics CT2X CTP sensor in the forum Environmental Sensors 2 months ago
Hi, has anyone used a Seametrics CT2X CTD sensor with a EnviroDIY datalogger? We are currently using these sensors and are looking into replacing some datalogger boxes.
-
Douglas Wood became a registered member 2 months ago
-
Elliot Ma replied to the topic Could not wake modem for clock sync in the forum Mayfly Data Logger 2 months, 1 weeks ago
Hi Shannon and Sara,
Thanks for taking a look at this. I actually JUST fixed it, and I’m not sure what I did correctly?
Nothing I did was able to wake the modem, and like Sara said, it wasn’t receiving power. I was in the midst of taking those photos you request Shannon, and I think just unplugging everything and plugging it back in fixed it……[Read more]
-
D_Manning replied to the topic Artifactual troughs and flickers in recorded stream depth in the forum Monitor My Watershed 2 months, 1 weeks ago
Thanks. Temperature coefficients, compensations – that’s interesting. I have the sensor sitting in a bucket of stream water right now – should see more rapid changes in temperature. I’ve a note into the METER Co.
-
neilh20 replied to the topic Artifactual troughs and flickers in recorded stream depth in the forum Monitor My Watershed 2 months, 1 weeks ago
I did some blog posts in 2016 with a number of depth sensors that quoted an error for a very wide temperature compensation. They where the Insitu LT500 (best), Keller Nanolevel, Keller Acculevel, Keller Level gage (worst).
I setup a situation with the depth sensors in a jar of water (low depth) with a good solar aspect to test how well they met…[Read more]
- Load More