nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 10 days ago
I spoke too soon. The Campbell ClariVUE10 eventually developed interval reporting issues with the last library that I mentioned above so I copied the libraries from my old computer onto my new computer because it was the last set of libraries that didn’t have issues. But now it is having interval reporting issues too and the CTD sensor readings…[Read more]
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger a month ago
Here are the results with the blue spirulina that has a known phycocyanin concentration (https://www.amazon.com/dp/B08XC7KSRP?ref=ppx_yo2ov_dt_b_fed_asin_title). PPB readings are still off.
Campbell ClariVUE10 reporting intervals seems to be resolved when I went back to a library I downloaded back in Nov 2024 but kept the SRC-sensors folder from…[Read more]
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger a month ago
We have been testing out the Turner C-FLUOR (PC) PHYCOCYANIN sensor and getting mixed results where we are not sure if it is the sensor, sketch, or something else.
When measuring pure di water we are getting readings of around 5 – 6 ppb in both an opaque jar and open jar with the sensor in a shade cap.
We bought blue spirulina (…[Read more]
-
nick started the topic Pelican 1120 drilling template in the forum Mayfly Data Logger a month ago
Can someone direct me to a 4 hole drilling template if it exist?
I found this: https://github.com/EnviroDIY/EnviroDIY_Mayfly_Logger/blob/master/hardware/1120Pelican_enviroDIY_5.pdf
I thought I found and bookmarked a 3 hole version before, but now I can’t seem to locate it.
Thank You
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 2 months ago
Since I am only using one C-FLOUR sensor, does having two pair of soldered resistors affect anything or should I redo the screw terminal board to only have one pair of resistors?
Thank you for the tip on needing two separate screw terminal boards because each C-FLOUR needing 2 ground terminals each.
-
nick replied to the topic Error Compiling for board EnviroDIY Mayfly 1284p in the forum Mayfly Data Logger 2 months ago
I was getting the same error message as the poster above, so I went ahead and followed the instructions that Shannon provided to fix it (2025-01-22 at 2:07 PM), but now I am getting this error message that I attached. That is one of 10ish errors that I am getting.
When checking out the libraries folder, everything seems in order.
The previous…[Read more]
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 2 months ago
<p style=”text-align: left;”>I’m just connecting one Turner phyco c-flour sensor.</p>
I assume these resistor pairs are independent and shouldn’t affect how a single sensor reports.
<p style=”text-align: left;”>Thank you for the previous response regarding the cable glands.</p> -
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 2 months ago
Shannon, I went ahead and soldered four 10k resistors instead of the two I originally said, similar to what you did here:
Does that still work for my purposes or does it change things?
Thank you.
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 4 months ago
Thank you for that info.
I need to tap another hole for the Turner device and was wondering if you have a size recommendation for a drill tap and waterproof cable gland.
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 6 months ago
Shannon,
Thank you for the confirmation and write up for the sketch setup. I just have the phycocyanin C-FLUOR. This is my first time soldering, so I’m practicing on another board before I commit on the MP screw terminal board.
Have you notice big differences between the calibration sheet versus your manual calibration? And for the manual…[Read more]
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 6 months ago
Shannon,
I attached a picture of how I am connecting the C-FLOUR to the multipurpose screw terminal board. Can you let me know if this is the correct wiring and resistor amount, type, and location?
Thank you.
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 6 months ago
<div>Hi Shannon,</div>
<div></div>
<div>I ordered a C-FLOUR not realizing that the modular sensor library only has compatibility with the Cyclops-7F, even though you mentioned the Cyclops in your earlier post.</div>
<div></div>
<div>Based on what a rep has told me, Turner is starting to phase out their Cyclops-7F sensors and replacing them with…[Read more] -
nick started the topic Continous HAB monitoring in the forum Mayfly Data Logger 10 months ago
Hi,
Has anyone setup their Mayfly data logger to monitor HABs in ponds/lakes? Right now, we are manually collecting the samples and trying to see if doing continuous monitoring would be beneficial.
Thank you.
-
nick replied to the topic Registering a new site on MMW in the forum Monitor My Watershed 2 years ago
@neilh20 I attached a screenshot of what I am entering to register a site. Am I missing something that is causing me this error?
I’m wondering if the account itself is the problem?
-
nick replied to the topic Registering a new site on MMW in the forum Monitor My Watershed 2 years ago
My sites didn’t get registered though. Can anyone else register a site to see if the error pops up?
-
nick started the topic Registering a new site on MMW in the forum Monitor My Watershed 2 years ago
I seem to be having issues with registering a new site on MMW where it is giving me this error: Server Error (500)
I tried on three different devices and three different browsers.
Is anyone else having this issue?
Thank you.
-
nick replied to the topic Upgrading boards at existing locations in the forum Mayfly Data Logger 2 years ago
@neilh20 Thank you for all of the info! It makes sense to create a dummy site on MMW so I can test without interfering with the production site. I will let you know how it turns out.
-
nick started the topic Upgrading boards at existing locations in the forum Mayfly Data Logger 2 years ago
I am going to be changing out a Mayfly datalogger board at an existing location and was trying to figure out the best approach in regard to data consistency. Since the location of the logger and sensors are the same, I will be using the existing UUIDs of the current site on MMW. I want to test out the board before deploying to see if the…[Read more]
-
nick started the topic FTDI and iOS devices in the forum Infrastructure and Equipment 2 years ago
Hi All,
I have been using android phones to connect a USB C -> FTDI cable to the FTDI port on the mayfly data logger to read data via the Serial USB Terminal app in the field.
Have any of you had success with connecting an iOS device (iPhone or iPad) to the mayfly data logger via cable?
Thank you.
-
nick started the topic CTD readings are 0.0 in the forum Mayfly Data Logger 6 years ago
I’m trying to troubleshoot a issue with the CTD or Mayfly data logger. I haven’t done anything yet, but just wanted to see if anyone has had this issue and what they did to fix it before I go out and troubleshoot.
2019-09-23 02:00:00,-5,622519200,17.5,4.08,260.0,18.6,290.0,2.9,2.4
2019-09-23…[Read more] - Load More