@w3asa
Active 4 months ago-
Jim Moore replied to the topic Monitoring power consumption in the forum Mayfly Data Logger 4 years, 2 months ago
I checked my GMI_EC5 station that I mentioned above that was not keeping up and I measured about 2.4 mA current draw when the mayfly is in sleep mode. I thought it should be close to zero when in sleep mode.
Any thoughts Shannon?
-
Jim Moore replied to the topic Monitoring power consumption in the forum Mayfly Data Logger 4 years, 2 months ago
I have the same issue. I have my LEC stations (GMI_ECxx) running with 2G cell service and I did have one station that the solar charge chip failed and caused battery to drop below the 3.55 volt threshold for upload. However GMI_EC5 seems to be getting a charge during the day but is still not keeping up. I attached a screen from MMW…[Read more]
-
Jim Moore replied to the topic Buy 20-25 Mayfly Data Loggers and Proto Shields in the forum Mayfly Data Logger 4 years, 3 months ago
I checked Amazon and finally discovered that “envirodiy mayfly protoshield” works for a search. Did not have envirodiy in my search query.
I just bought the last one so guess time to restock
-
Jim Moore replied to the topic Buy 20-25 Mayfly Data Loggers and Proto Shields in the forum Mayfly Data Logger 4 years, 3 months ago
I checked Amazon and finally discovered that “envirodiy mayfly protoshield” works for a search. Did not have envirodiy in my search query.
-
Jim Moore replied to the topic Buy 20-25 Mayfly Data Loggers and Proto Shields in the forum Mayfly Data Logger 4 years, 3 months ago
<h2 class=”user-nicename”>@shicks</h2>
I just checked Amazon and no Protoshields showing. I guess shipment processing isn’t one day turnaround! -
Jim Moore replied to the topic Buy 20-25 Mayfly Data Loggers and Proto Shields in the forum Mayfly Data Logger 4 years, 4 months ago
Any updates on the availability of the Protosheilds?
-
Jim Moore replied to the topic Low Cost EC sensor Station upgrade in the forum Mayfly Data Logger 4 years, 5 months ago
Thanks. I am using the FTDI port and wiggled some plugs, etc and now is loading ok. I assume when I was getting that error the mayfly was plugged in and turned on because when I attempt to load with the pwr switch turned off I get the following e…[Read more]
-
Jim Moore replied to the topic Low Cost EC sensor Station upgrade in the forum Mayfly Data Logger 4 years, 5 months ago
Hi Sara @srgdamiano
I haven’t used PIO for several months but in preparation for the transition from 2G to 4G I launched PIO this week and it apparently did an upgrade and now my code won’t load.
I get the following error:
avrdude: stk500_getsync() attempt 10 of 10: not in sync: resp=0x00
PIO is currently core 4.3.4 and home 3.2.3
An…[Read more]
-
Jim Moore wrote a new post 4 years, 5 months ago
One area of vulnerability for EnviroDIY Monitoring Stations is rodent damage and in particular beavers! The cables for the solar panel can be repaired fairly easily if chewed by squirrels but if a rodent chews the […]
-
Jim Moore replied to the topic MMW Data Outage? in the forum Monitor My Watershed 4 years, 5 months ago
Since it’s not a MMW issue should I move my technical questions back to my original post on “infrastructure and equipment” forum?
-
Jim Moore replied to the topic MMW Data Outage? in the forum Monitor My Watershed 4 years, 5 months ago
Thanks for the update, Shannon. Are there any plans to buy a quantity of 4G hardware in the expectation of a discount? I will need at least 8 and would be glad to help out where needed.
-
Jim Moore replied to the topic MMW Data Outage? in the forum Monitor My Watershed 4 years, 5 months ago
I reposted this here from my post this morning on “infrastructure and equipment” forum:
“I noticed that what appears to be a general shutdown of the 2G network in the N. Chester county area which occurred Sunday, 7/12, at 13:45 EDT. I have 8 stations in the Great Marsh Institutes’s network. Three of these woke up this morning but the othe…[Read more]
-
Jim Moore started the topic Status of 2G network? in the forum Infrastructure and Equipment 4 years, 5 months ago
I noticed that what appears to be a general shutdown of the 2G network in the N. Chester county area which occurred Sunday, 7/12, at 13:45 EDT. I have 8 stations in the Great Marsh Institutes’s network. Three of these woke up this morning but the others are still mute.
According to Hologram it looks like 2G is on borrowed time
Does anyone h…[Read more]
-
Jim Moore replied to the topic Buy 20-25 Mayfly Data Loggers and Proto Shields in the forum Mayfly Data Logger 4 years, 5 months ago
Amazon says the protoshield is unavailable. Are there any plans to restock? I need 2-3 protoshields.
-
Jim Moore replied to the topic Low Cost EC sensor Station upgrade in the forum Mayfly Data Logger 4 years, 7 months ago
Thanks Chuck for getting my Sensorex RTD voltage divider output converted to °C. I plan to leave the EC as the raw value from the AtlasScientific EZO circuit. Attached is the code addition to DRWI_CitSci.ino to get the Sensorex probe data published to MonMW:
//================================================== // Atlas Scientific EZ…
-
Jim Moore replied to the topic Geographically Scaling Modular Sensors in the forum Mayfly Data Logger 4 years, 8 months ago
-
Jim Moore replied to the topic Low Cost EC sensor Station upgrade in the forum Mayfly Data Logger 4 years, 8 months ago
<h4 class=”user-nicename”>@chuckkir</h4>
Thanks Chuck for offering to help with my coding issues. I have two sets of code that I am currently testing with my Low Cost Sensor Station. Simple_logging.ino is working on my mayfly platform which I am using to test the compensation routines to convert the raw data from the AtlasScientific EC sensor a…[Read more] -
Jim Moore replied to the topic Geographically Scaling Modular Sensors in the forum Mayfly Data Logger 4 years, 8 months ago
I am currently working on setting up an array of Low Cost EC sensor Stations in Great Marsh, N. Chester County to monitor UNTs flowing into this large wetland. My current issues are compensating the raw sensor data to µS and ºC. See my forum thread.
I currently have six stations and will probably add more all using the the same operating cod…[Read more]
-
Jim Moore replied to the topic Mayfly 16 bit ADC errors in the forum Mayfly Data Logger 4 years, 8 months ago
Where did the calibration coefficients you used in line 31 come from? They could be in error. The raw value of adc0 in line 26 is a bit count and 65536 (2^16) is the maximum which would be the value output if the analog input was connected to Vdd (~3.3V).
Don’t know why the zero offset. I would try printing out your raw adc0 with the analog in…[Read more]
-
Jim Moore replied to the topic Low Cost EC sensor Station upgrade in the forum Mayfly Data Logger 4 years, 8 months ago
Hi Adam-
Thanks for getting back to me. Since my software expertise is limited and I don’t understand how all the code in ModularSensors works I have not been able to get “calculated variable” to compile in my simple_logging.ino code. I have been successful in getting the code to work with external_voltage and the Atlas EZO c…[Read more]
- Load More
Thanks for the posting. In N California I’ve had a squirrel chew through some power wiring at one site. I think in the end it was to do some armored flexible PVC tubing.